IXXAT CANbridge NT420

1,144,000 부가세포함

Configurable CAN-to-CAN Bridge/Router with CAN FD Support.

수량
총 금액

CANbridge NT420

본 제품은 주문생산 제품으로 발주 후 고객 사정에 의한 발주 취소가 불가합니다.

Configurable CAN-to-CAN Bridge/Router with CAN FD Support

The CANbridge NT is offered in two versions, as CANbridge NT 200 with 2 classic CAN channels and as CANbridge NT 420 with 4 CAN channels, where 2 channels can be switched between CAN and CAN FD. 
Both devices allow the easy coupling of CAN (CAN FD) networks, including networks with different bit rates or frame formats (11/29 bit identifier). The bridges/routers have a powerful microcontroller that can perform message filtering, ID translation and data multiplexing (e.g. required for CAN FD to CAN message conversion), at this even bursts at higher data rates can be processed without message loss.

FEATURES AND BENEFITS

FEATURES

  • Up to 4 CAN (2 CAN FD) channels in one device
  • Powerful filter, ID translation, data mapping and multiplex functionality
  • Execution of pre-defined actions using event-triggered "Action Rules"
  • Programming of any kind of action rules using LUA
  • Configurable security levels for device access (configuration or firmware upload)
  • Windows configuration tool for easy configuration via USB

BENEFITS

  • Easy coupling of CAN and CAN FD systems and devices
  • Cost savings due to simple wiring
  • Allows system expansion and tree/star topologies
  • Increased system reliability
  • Line protection by galvanic isolation

 

HOW IT WORKS

Unlike a CAN Repeater, which only translates the electric signals, the CAN messages are received completely by the CANbridge NT and then sent to the other CAN or CAN FD network in line with existing filter, conversion, port mapping or multiplex rules (Store-Forward principle). With two CANbridge NT 420 it is possible to transmit messages between two Classic CAN networks via a CAN FD network (CAN tunnel).

 

CANbridge NT 200 Network CANbridge NT 420 Network 

Filtering and multiplexing
By using mapping tables the message reception/transmission is possible between all 4 channels. With the aid of filter and conversion rules, CAN or CAN FD messages can be filtered or modified. With these mechanism, the bus load can be reduced in the individual networks by only sending messages which are of interest to the other network. For SAE J1939 applications a special mapping table is provided, adapted to the specific parameters. The data multiplexing/demultiplexing functionality enables the mapping of e.g. CAN-FD data to several standard CAN messages and vice versa. 

Action Rules
In response to received messages, device or CAN bus status events, a variety of actions can be performed automatically, e.g. sending messages (CAN, CAN FD), changing device settings or switching device LEDs. Action rules are created through intuitive drop-down menus for events and actions within the Windows-based device configuration tool or by using LUA scripts.

Cyclic transmission
The cyclic transmission feature enables cyclic forwarding of messages. Both, messages and cycle times are defined within a central cyclic transmission table. 

CONFIGURATION

The configuration of the CANbridge NT and the firmware upload is done with an intuitive to operate Windows configuration tool via USB. With the tool, the configuration of filter, mapping, multiplexer or translation rules can be carried out very easily, without programming skills.

CAN@Net NT and CANbridge NT Configuration Tool
Windows configuration tool supporting CANbridge NT and CAN@net NT

TECHNICAL SPECIFICATIONS

CAN bitrates
5 to 1000 kBit/s 
CAN FD bitrates
Arbitration rate up to 1000 kBit/s, data rate up to 8000 kbit/s. The data rates are verified by tests. User-defined bit rates are possible.
Attention: The maximum data rate can be exceeded depending on the concrete operating conditions (cable length, settings made, remote stations,...), but it can also not be reached.
CAN bus termination resistorNone
Max. number of bus nodes120
Power supply9 V to 36 V DC
Current consumptionTypically 110 mA (at 24 V input voltage) or 220 mA (at 12 V input voltage)
Galvanic isolation1 kV for 1 sec
Operating temperature-40 °C to +85 °C
Protection classIP20
Dimensions114.5 x 99 x 22.5 mm
WeightApprox. 150 g
CertificationCE, FCC, UL

 

제조사 : IXXAT (독일)

 

납기 : 약 10 ~ 30 일

 

AS 방침 : 유상 

번호 제목 답변여부 작성자 작성일
등록된 상품 문의가 없습니다.
반품/교환 안내

- 반품불가 표시된 상품 또는 해외 수입 제품은 제품의 불량 이외의 어떠한 사유로도 교환이나 반품이 되지 않습니다.

- 제품 특성상 고객님께서 제품을 충분히 확인하시고 주문하셔야 합니다. 쇼핑몰의 사진이나 설명은 단순 참고용 입니다.

- 해외 수입 제품이 아닌 경우 단순변심, 주문오류 등에 의한 반품 및 교환은 상품 수령일로 부터 7일 이내에 미개봉, 미사용, 미설치 된 제품에 한하여 교환이 가능합니다.

- 단순변심에 의한 반품 및 교환의 경우, 반품 및 교환을 위하여 추가로 발생되는 운임은 고객님 부담입니다.

- 배송박스가 훼손 되었거나, 제품이 파손된 경우 배송한 택배기사에게 즉시 알리고, 사진(파손부분, 송장부분)을 찍어 고객센터로 보내 주시기 바랍니다.

- 배달된 상품이 파손 되었거나, 기능상 불량, 하자가 있을 경우 상품수령일로 부터 7일 이내에 고객센터에 접수해 주시기 바랍니다.


배송 안내

- 결재금액이 5만원 미만은 배송비가 3,000원이며, 5만원 이상은 배송비가 무료입니다.

- 재고상품의 경우 주문 후 평균 2~3일내 (토요일, 공휴일 제외) 수령 가능하며, 택배사의 사정에 따라 다소 지연될 수 있습니다.

- 주문상품의 경우 평균 1~2주 기간이 소요 됩니다.

- 오후 3시 이후 입금 확인건은 다음날 주문 처리 됩니다.